eduzhai > Helth Sciences > Medical >

Application of digital measurement of human pupil dynamics under light stimulation in medical application and research

  • sky
  • (0) Download
  • 20211031
  • Save
https://www.eduzhai.net American Journal of Biomedical En gineer in g 2013, 3(6): 143-147 DOI: 10.5923/j.ajbe.20130306.03 Digital Measurement of the Human Pupil's Dynamics under Light Stimulation for Medical Applications and Research David Asael Gutiérrez Hernández1,*, Juan Arturo Aranda Ruiz2, Jorge Ramón Parra Michel1 1Escuela de Ingenierías. Universidad De La Salle Bajío. Av. Universidad 602, Col. Lomas del Campestre, León, Gto. M éxico 2Unidad Profesional Interdisciplinaria de Ingeniería campus Guanajuato. Instituto Politécnico Nacional. Av. M ineral de Valenciana No. 200. Col. Fracc. Industrial Puerto Interior, Silao de la Victoria, Gto, M éxico Abstract The human body can be affected for different kinds of diseases. A disease is always associated with specific symptoms and signs. It may be caused by factors that can co me fro m an external source or by internal dysfunctions. The pupil changes of diameter and shape, as well as the pupil reaction to light and darkness are factors that become an important way to know and understand different diseases and how they affect the human body. In this work we propose an optoelectronic device that measures the pupil changes due to external light stimu lations. A video camera is placed to record the pupil changes of diameter wh ile this is stimulated by light pulses on red, green, blue and white. The pupil is placed in an initial diameter by means of a dark cabin, this will allow the measures to be more precisely, and then it is stimu lated by the wavelength above mentioned. The results are shown in a graphic interface (software) designed for this development where, also, the pupil changes are shown in real time . Keywords Optoelectronics, Medical Applications, Pupil Dynamics, Pupil Diameter 1. Introduction The pupil is a sma ll hole that is located in the center of the iris, its main function is to allow light to enter in the lens of the eye. The principal characteristics of the pupil to be considered for researching objectives are the diameter of the pupil, wh ich is controlled by smooth muscle within the iris; the pupillary size, shape, and reactiv ity to light that are regulated by the autonomic nervous system[1]. The diameter of the pupil is controlled by the pupilloconstrictor and the pupillodilator muscles which are controlled in turn by the parasympathetic nervous system and the sympathetic nervous system res pectively[2]. In the Parasympathetic Response, also known as Pupillary Constriction, when light enters into the eye, the cones and rods of the retina serve as sensory receptors and send the impulse via afferent nerve pathways through axons in the optic nerve, optic chiasm, and optic tract[3]. This impulse reaches the Edinger–Westphal nuclei in the midbrain. The parasy mpathetic response orig inates in these nuclei, and efferent nerve path ways trans mit the impu lse v ia cran ial nerv e III to the pup illo constricto r muscle[4]. Bo th t he * Corresponding author: dgutierrez@ipn.mx (David Asael Gutiérrez Hernández) Published online at https://www.eduzhai.net Copyright © 2013 Scientific & Academic Publishing. All Rights Reserved ipsilateral and the contralateral Edinger–Westphal nuclei receive identical a fferent input, which causes the consensual light reflex[5]. For the Sy mpathetic Response, known as Pupillary Dilation, the sympathetic pathway responsible for pupil dilation is orig inated in the posterior-lateral hypothalamus and involves 3 neurons[4]. The first ipsilatera l preganglionic central neuron travels through the lateral b rainstem to the spinal cord. The second preganglionic neuron crosses the lung apex and ascends the neck where it synapses in the cervical ganglion. The third postganglionic neuron accompanies the internal carotid into the skull base to the trigeminal ganglion and joins the nerve fibers of the abducens as it passes through the inferior o rbital fissure. This neuron then continues through the trigeminal nerve until it reaches the pupillodilator muscle in the iris. The neurotransmitter responsible for this synaptic reaction is norepinephrine[6]. The eye is innervated by 3 cranial nerves (CN), III, IV, VI, which work together to provide smooth eye movements. The oculomotor Cran ial nerve III is in charge of controlling constriction due to the parasympathetic response of the pupil[7]. Cran ial nerves III, IV, and VI are the responsible for ext raocular eye movements (EOMs) because they innervate the muscles surrounding the eye. In other words, the pupil is controlled by a nerve pathway in the body which starts in the brain, travelling down the 144 David Asael Gutiérrez Hernández et al.: Digital M easurement of the Human Pupil's Dynamics under Light Stimulation for M edical Applications and Research spinal cord, up over the top of the lung and under the subclavian artery and through extensions of the brain and finally travels close to the optic nerve and then to the pupil. Any interruption presented along this pathway can change the pupillary reaction. There are many conditions that could affect the pupil size. Some of these conditions are the result of a disease. For example, a mid -dilated pupil could represents a glaucoma; in brain tumors, if the tumor is near the origin of the pupillary nerve fibers could generate some problems within the pupil; the use of recreational drugs or med ications can sometimes provoke the pupils to dilate or constrict abnormally, effects that are also caused by an aneurysm that pushes on certain blood vessels in the brain. Specific research around a specific disease has been done by studying the pupil responds, for examp le, the change of the pupil’s light reflex and mob ility in Parkinson’s disease patients with and without cognitive disorder has been reported[8]. A pupillary examination in patients with traumatic brain inju ries and its associated physiologic response is studied in[6]. Other examp le of research concerning the pupil change of size, does a study over mo re than 100 children liv ing with diabetes where the size of the pupil has a significant content of informat ion[9]. The authors of this work conclude that diabetic ch ildren had a significantly smaller median pupillary diameter, measured as the ratio between pupil and iris, than control children. Hu man beings have an interval of light color distinctions. This is based on the existence of three types of retinal receptor cells called cones sensitive to short waves, starting fro m 400 nanometers, corresponding to the range of blues and violets, sensitive to med iu m waves, which are around 550 nanometers in the range of greens and also responsive to long waves that are found in more than 600 nano meters and correspond to the range of cells. When excited in the whole fie ld of long-wave rece ivers (R) is the visual sensation of red when e xcited in the whole fie ld of mediu m wave receivers (V) is the visual sensation of green and when excited in the whole field of shortwave receivers (A) is the visual sensation of blue, for that reason it is impossible even to find equivalence or balance between the three. Considering the interval of light that human beings can tell, in this work, an optoelectronic device is design and built to give the graphs obtained by measuring the diameter of the human pupil when stimulated at 400, 550 and 600 nanometers versus time of capture. Results are presented for a couple of measurements in a couple of patients which conditions are not important for this work. 2. Design and Development of the Optoelectronic Instrument There were so me considerations for the correct design and construction of the optoelectronic device. 1) the pupil must be in total darkness to ensure pupil stability and to know the diameter of the pupil under dark conditions 2) The whole event has to be recorded, this means that the initial diameter has to be recorded and from there, all the variations on the pupil diameter due to the external light that, for th is experiment, is co ming fro m 3 light-emitting diodes corresponding to Red (R), Green (G) and Blue (B) colors as it is described above. The light stimu lation responses, electronically, to a controlled sequence of pulses coming fro m a programed software in order to ensure a high precision method. 3) A camera sensor has to be considered into the optoelectronics design. 4) Due to the darkness condition, it will be impossible for the camera sensor to record any pupil change; in this case, a couple of Infrared Light-Emitt ing Diodes (IR LED) have to be placed in the device. Figure 1 shows the setup used in this work. PUSH RGB LED IR LED WEB CAM WHITE LED PUPIL Figure 1. Experimental set up for measuring the pupil diameter changes along the time As it can be seen, in figure 1, the electronics are inside a dark cabin in order to stabilize the pupil to an initial diameter and also to keep a control on the measure to be done. After a period of time, the RGB led illu minates the eye, first the red light is switched on, then the green and last the blue light that give to the pupil an e xterna l stimulation that causes changes in its diameter. A white light stimulation is also projected to the eye after the RGB light stimu lation. These changes are recorder by a web camera sensor that is plug into a computer by a USB port, wherein, by means of a computer program, a graph shows the response of the change in pupil diameter versus time and due to external light stimu lations in the RGB co lor model. The eye is all the time illu minated by the IR Led with the intention to allow the camera sensor to watch the pupil; otherwise, it would be impossible to watch it due to dark cabin. The camera sensor is set up to 30 frames per second (fps), American Journal of Biomedical En gineer in g 2013, 3(6): 143-147 145 which g ives the possibility to have a high speed study of the pupil diameter changes by recording data every 33ms. The functionality of the electronics is controlled by an external data acquisition device which emp loys a bidirectional communicat ion with the computer program according to figure 2. USER BEGINS PROCESS by the push button. Computer program turns on the DAQ device and the camera sensor. DAQ begins sequence to t RED to t GREEN t W HI TE to t BLUE to to DAQ stops sequence Computer program acquires and process data information from the camera sensor. Computer program displays the results on a graphic. Figure 2. Structure of the optoelectronics device for measuring pupil dynamics The user turns on the computer program, once it is on, the computer program turns on the DAQ device as well as the camera sensor. The DAQ begins the external light stimulat ion sequence, first, a time in darkness, to, is used to stabilize the pupil diameter, after that, a red light is projected to the eye for a t ime, tRED, a new time in darkness is used to let the pupil to resting, then a time with green light projected is on and so on until the sequence is done. At the same time of the sequence, the computer program acquires and processes the data coming fro m the camera sensor; at the end of the process the computer program displays a diameter versus time graph. The built instrument is shown in figure 3. The built instrument is shown in figure 3. First, it was modeled in a 3D software and then it was built in a 3D printer to keep with the designed s p ecificatio n s . Figure 3. Optoelectronic device for monitoring pupil changes 146 David Asael Gutiérrez Hernández et al.: Digital M easurement of the Human Pupil's Dynamics under Light Stimulation for M edical Applications and Research 3. Results Figure 4 shows the sequence of pulses of light that are used to stimu late the pupil. These pulses are electronically controlled to turn on and turn off the LEDs. X-axis is in seconds and Y-axis is in meters. The resulted graphic, shown in figure 4, represents the changes on the diameter o f the pupil along the time. It is important to mention that the time on darkness, to and the time with light on, tRED, tGREEN, tBLUE, can be configured in the computer program, x – axis is in seconds, y – axis is the diameter of the pupil measuring in meters. As it is shown, the resulted graph contains 4 peaks representing the pupil reaction to external stimu lation of light in RGB color model and white light stimu lation. This kind of non-contact measurement can help to the study and diagnostic of different diseases on the human body. Because this measurement is a digital one, all the data can be mathematical processed to have a good quality correlation to all the different diseases to be studied for future works. The computer interface, figure 6, shows the results of the pupil changes of diameter and area along the time. Figure 4. Sequence of light pulses electronically controlled to stimulate the pupil Figure 5. Pupil reaction lo RGB light stimulation Figure 6. The interface used together with this optoelectronic device shows the pupil and its reaction in real time during the measurements. The couple of graphics shown the reaction of the diameter and the area of the pupilto light stimulation against time American Journal of Biomedical En gineer in g 2013, 3(6): 143-147 147 4. Conclusions REFERENCES The proposed optoelectronic device has big advantages; is [1] Centers for Disease Control and Prevention, Division of a non-contact, fast, economic and secure way to study Injury and Disability Outcomes and Progress. Traumatic diseases on the human body. brain injury in the United States: emergency department visits, hospitalizations, and deaths.[Online]. Available: The resulted graph gives a very clear idea of how the ht tp ://www.cdc.gov/ncip c/p ub-res/T BI_in_US_04/T BI-USA changes on the pupil diameter along the time and due to _Book-Oct 1.p df. external light stimulations can be correlated to neurological reactions. This is a novel idea that can help for opportune [2] Centers for Disease Control and Prevention, National Center for Injury Prevention and Control. Injury topics and fact diagnostics and to follow particular diseases with the sheets: traumatic brain injury.[Online]. Available: http://ww objective to improve the quality of people life. w.cdc.gov /ncip c/fa ct sheet s/t bi.ht m. It is important to mention that the pupil reactions are related to different conditions ranging fro m iris atrophy, eye [3] Barker E. Neuroscience Nursing. St Louis, M O: M osby; 2001;45:60–78, 334–335. surgical procedures or any other ocular condition that may affect the performance of the described device making the [4] Hickey J. The Clinical Practice of Neurological and results highly unpredictable, however, because of the digital measuring co ming fro m this device, this kind of conditions NeurosurgicalNursing. 5th ed. Philadelphia: Lippincott Williams &Wilkins; 2003:132–135, 170–176. could be considered before the application of the device for a [5] Gilman S, Newman S. Manter and Gatz’s Essentials of specific study or disease evaluation to generated a proper research method and an adequate processing of the acquired ClinicalNeuroanatomy and Neurophysiology. Philadelphia: FA Davis; 2003. data. [6] Andrea Adoni, M olly M cNett, “The pupillary response in traumatic brain injury: A guide for trauma nurses”, Journal of trauma nursing, 14(4), 2007:191–196. ACKNOWLEDGEMENTS [7] M arch K, Wellwood J, Lovasick D, M adden L, Criddle L, The authors wants to acknowledge to the Centro de Henrickson S. Craniocerebral trauma. In: Bader M , Littlejohns L, eds. AANN Core Curriculum for Neuroscience Biotecnología Óptica Aplicada y Asociados and the Consejo Nurses. 4th ed. St Louis, M O: Saunders; 2004:277–334. de Ciencia y Tecnología del Estado de Guanajuato (CONCYTEG – Pro ject 168731) for their support in this work. [8] Stergiou V, Fotiou D, Tsiptsios D, Haidich B, Nakou M , Giantselidis C, Karlovasitou A. Pupillometric findings in patients with Parkinson's disease and cognitive disorder, Int J Psychophysiol. 2009; 72(2), 97-101. [9] K Karavanaki, A G Davies, L P Hunt, M H M organ, J D Baum, Pupil size in diabetes, Archives of disease in Childhood. 1994; 71: 511 – 515.

... pages left unread,continue reading

Document pages: 5 pages

Please select stars to rate!

         

0 comments Sign in to leave a comment.

    Data loading, please wait...
×